Datalogic - CSME-03VU24-Y14 - Safety Relay Module
The Datalogic CSME-03VU24-Y14 is a cost-effective safety relay module designed for use with Datalogic’s SG and SE series light curtains that feature External Device Monitoring (EDM). This relay does not have internal monitoring; therefore, EDM control is mandatory. By utilizing the CSME relay, the OSSD outputs from the safety light curtain can be converted to potential-free relay contacts. With proper EDM connection, it maintains the same safety level as the connected safety light curtain.
Key Features:
• Compatibility: Designed to work seamlessly with Datalogic’s SG and SE series light curtains equipped with EDM functionality.
• Safety Outputs: Equipped with three normally open (NO) force-guided relay contacts and one normally closed (NC) contact for EDM.
• Compact Design: Housed in a polyamide PA 6.6 enclosure with a compact form factor, suitable for DIN rail mounting.
• LED Indicators: Features two LEDs for status indication, facilitating easy monitoring of operational status.
Technical Specifications:
• Supply Voltage: 24 V DC (±20%)
• Rated Power Consumption: < 2 W (max)
• Start Power Consumption: < 3 W (max)
• Safe Outputs: 3 NO force-guided relay contacts + 1 NC contact for EDM
• Maximum Switching Current: 6 A
• Maximum Switching Voltage: 230/240 V AC, 300 V DC
• Disconnection Time: 40 ms
• Ingress Protection Class: IP40 (housing), IP20 (terminal block)
• Operating Temperature: –25 °C to +55 °C
• Material: Housing made of Polyamide PA 6.6 class V0 (UL94)
• Dimensions (L x H x D): 111.5 mm x 99.0 mm x 22.5 mm
• Weight: Approximately 200 g
• Mechanical Endurance: > 10 million operations
• Electrical Endurance: > 100,000 operations
• Standard Conformity: Complies with EN 60204-1, EN 954, EN 999, EN 1037, EN ISO 12100-1, EN ISO 12100-2, EN 418, EN 60529, EN 61000-6-2, EN 61000-6-3, EN 62326-1, EN 60664-1, EN 60947-1, UL 508, CSA C22.2 No. 14-95
• Approvals: CE-marking, UL file E131787
Applications:
• Safety Light Curtains: Ideal for converting OSSD outputs from safety light curtains to potential-free relay contacts in industrial safety applications.
• Machine Safety Systems: Enhances safety in machinery by providing reliable relay outputs for safety-related controls.