{"product_id":"sigmatek-sro-021-s-dias-safety-relay-output-module-2x-no-sil3-pl-e","title":"Sigmatek - SRO 021 - S-DIAS Safety Relay Output Module, 2x NO, SIL3 \/ PL e","description":"\u003cp class=\"p1\"\u003eThe Sigmatek SRO 021 is a safety relay output module from the S-DIAS series, engineered for applications requiring high safety standards. It provides two normally open (NO) relay outputs, each capable of handling up to +30 V DC at 6 A. Certified for SIL 3 (EN IEC 62061) and Performance Level e, Category 4 (EN ISO 13849-1\/-2), the SRO 021 ensures reliable operation in safety-critical systems. \u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp class=\"p3\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp class=\"p4\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003c\/b\u003e\u003c\/span\u003e SRO 021\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eBrand:\u003c\/b\u003e\u003c\/span\u003e Sigmatek\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cb\u003eArticle Number:\u003c\/b\u003e\u003cspan class=\"s1\"\u003e 20-893-021\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eRelay Outputs:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cb\u003eNumber:\u003c\/b\u003e\u003cspan class=\"s1\"\u003e 2\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eType:\u003c\/b\u003e\u003c\/span\u003e Normally Open (NO)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eVoltage Range:\u003c\/b\u003e\u003c\/span\u003e Up to +30 V DC\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eMaximum Current:\u003c\/b\u003e\u003c\/span\u003e 6 A at 55 °C; 4 A at 60 °C\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eResponse Time:\u003c\/b\u003e\u003c\/span\u003e Typically 10 ms\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eFall Time:\u003c\/b\u003e\u003c\/span\u003e Typically 3 ms\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eShort-Circuit and Overload Protection:\u003c\/b\u003e\u003c\/span\u003e External fuse category gG, maximum 6 A\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eSafety Certifications:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003eSIL 3 (EN IEC 62061)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003ePL e, Category 4 (EN ISO 13849-1\/-2)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003eUL 508 (E247993)\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eMechanical Features:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eDimensions (W × H × D):\u003c\/b\u003e\u003c\/span\u003e 25 mm × 104.2 mm × 72 mm\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eMounting:\u003c\/b\u003e\u003c\/span\u003e DIN rail\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cb\u003eProtection Class:\u003c\/b\u003e\u003cspan class=\"s1\"\u003e IP20\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eEnvironmental Conditions:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eOperating Temperature:\u003c\/b\u003e\u003c\/span\u003e 0 °C to +55 °C (up to +60 °C with derating)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cb\u003eStorage Temperature:\u003c\/b\u003e\u003cspan class=\"s1\"\u003e -20 °C to +85 °C\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eHumidity:\u003c\/b\u003e\u003c\/span\u003e 0–95%, non-condensing\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eAltitude:\u003c\/b\u003e\u003c\/span\u003e 0–2000 m without derating; above 2000 m, derate maximum temperature by 0.5 °C per 100 m\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eElectrical Requirements:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cb\u003eVoltage Supply from Safety Bus:\u003c\/b\u003e\u003cspan class=\"s1\"\u003e +12 V and +24 V\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eCurrent Consumption:\u003c\/b\u003e\u003c\/span\u003e Typically 30 mA (+12 V), 90 mA (+24 V)\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/span\u003e Ideal for switching higher power loads or potential-isolated circuits, such as hydraulic valves or emergency stop circuits, in safety-critical industrial automation systems.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"Sigmatek","offers":[{"title":"Default Title","offer_id":55818364944758,"sku":"EB-286669234594","price":208.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_9b5911f9-2e6a-43ad-9551-61ac12025a12.jpg?v=1750716392","url":"https:\/\/volt-werk.com\/products\/sigmatek-sro-021-s-dias-safety-relay-output-module-2x-no-sil3-pl-e","provider":"VOLTWERK Handel","version":"1.0","type":"link"}