{"product_id":"schneider-electric-bcpma224s-1b-powerlogic-branch-circuit-power-monitor","title":"Schneider Electric – BCPMA224S (1B) – PowerLogic Branch-Circuit Power Monitor","description":"\u003cp class=\"p1\"\u003eThe \u003cspan class=\"s1\"\u003e\u003cb\u003eSchneider Electric BCPMA224S 1B\u003c\/b\u003e\u003c\/span\u003e is a branch-circuit power and energy monitoring unit from the PowerLogic BCPM Advanced series. Designed to measure power quality, voltage, current, and energy in multiple circuits, it features built-in 100 A solid-core CTs and supports Modbus RTU over RS‑485—ideal for use in power distribution panels and energy metering systems. The “1B” suffix typically denotes an alternate configuration or version of the base BCPMA224S; however, specific differences (e.g., CT secondary rating or communication enhancements) are not explicitly stated in publicly available documentation.\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch3\u003e\u003cb\u003eKey Technical Specifications\u003c\/b\u003e\u003c\/h3\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eDevice Type:\u003c\/b\u003e\u003c\/span\u003e Multi‑circuit energy meter – PowerLogic BCPM Advanced\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel \/ MPN:\u003c\/b\u003e\u003c\/span\u003e BCPMA224S (1B variant)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eCT Configuration:\u003c\/b\u003e\u003c\/span\u003e 24 solid-core CTs, 100 A rating, arranged with 18 mm spacing \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSupply Voltage:\u003c\/b\u003e\u003c\/span\u003e 90–277 V AC (phase-to-neutral), 150–480 V AC (phase-to-phase); ±1 % accuracy \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eMeasurement Capabilities:\u003c\/b\u003e\u003c\/span\u003e Voltage, current, frequency, active power, power factor, active energy, voltage sag\/swell detection \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eAccuracy:\u003c\/b\u003e\u003c\/span\u003e Branch current:\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e1 % for 2–100 A\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e2 % for 0.25–2 A\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eMains current: 3 % for both 1–100 % and 2–100 % ranges; Voltage: 1 % for 90–277 V \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSampling \u0026amp; Update:\u003c\/b\u003e\u003c\/span\u003e 256 samples per cycle; data refreshed every ~1.8 seconds \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eCommunication:\u003c\/b\u003e\u003c\/span\u003e Modbus RTU over RS‑485; alarms include high\/low current, over\/under voltage, etc. \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eMounting:\u003c\/b\u003e\u003c\/span\u003e Panel-mounted in enclosures; rugged design suitable for sub-billing and data center energy monitoring \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eEnvironmental Specs:\u003c\/b\u003e\u003c\/span\u003e Operating temp: 0–60 °C; storage: –40–70 °C; humidity up to 95 %; altitude: up to 3,000 m \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eCertifications:\u003c\/b\u003e\u003c\/span\u003e UL 508, EN 61010, ANSI C12.1, IEC 61036 \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eDimensions \u0026amp; Weight:\u003c\/b\u003e\u003c\/span\u003e Width ~288 mm, Height ~146 mm, Weight ~1.5 kg  \u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":56403740262774,"sku":"EB-286856194061","price":1899.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_882a7a11-f576-4438-b4e1-d8fad42b892d.jpg?v=1759849045","url":"https:\/\/volt-werk.com\/products\/schneider-electric-bcpma224s-1b-powerlogic-branch-circuit-power-monitor","provider":"VOLTWERK Handel","version":"1.0","type":"link"}