{"product_id":"abb-dmtme-i-485-96-2csg163030r4022-96-96-mm-multifunction-panel-meter","title":"ABB – DMTME-I-485-96 (2CSG163030R4022) – 96×96 mm Multifunction Panel Meter","description":"\u003cp class=\"p\"\u003eThe ABB DMTME‑I‑‑ is a versatile digital panel meter designed for comprehensive electrical monitoring in industrial and commercial power systems. Equipped with True RMS measurement, RS‑ Modbus RTU communication, and two configurable outputs (pulse or alarm), it supports both single‑ and three‑phase mains and offers up to  different electrical parameters via a four‑digit LED display.\u003c\/p\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch\u003e\u003cb\u003e Key Features\u003c\/b\u003e\u003c\/h\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003cb\u003eModel:\u003c\/b\u003e\u003c\/span\u003e DMTME‑I‑‑ (ABB P\/N CSGR) \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003cb\u003ePanel Cut‑out:\u003c\/b\u003e\u003c\/span\u003e  ×  mm, depth ~ mm\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003cb\u003ePower Supply:\u003c\/b\u003e\u003c\/span\u003e – V AC or  V AC, – Hz; \u0026lt; VA\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p\"\u003e\u003cb\u003eMeasurement Scope:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p\"\u003e– Voltage (L‑N, L‑L): – V AC RMS\u003c\/p\u003e\n\u003cp class=\"p\"\u003e– Current via CTs (typically  A primary)\u003c\/p\u003e\n\u003cp class=\"p\"\u003e– Power (P, Q, S), PF, frequency, plus min\/max\/avg statistics \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003e\u003cb\u003eTrue RMS Accuracy:\u003c\/b\u003e\u003cspan class=\"s\"\u003e Class % \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003cb\u003eDisplay \u0026amp; Navigation:\u003c\/b\u003e\u003c\/span\u003e Four red LED displays for phase and system values; scan and reset functions \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003cb\u003eRS‑ Interface:\u003c\/b\u003e\u003c\/span\u003e Galvanically isolated Modbus‑RTU; address and baud configurable \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003cb\u003eOutputs (x):\u003c\/b\u003e\u003c\/span\u003e Relay or pulse outputs for kWh\/kVArh or parameter threshold alarms \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003cb\u003eCT\/VT Configuration:\u003c\/b\u003e\u003c\/span\u003e Programmable ratios (CT: –A; VT: –V) \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003cb\u003eParameterization:\u003c\/b\u003e\u003c\/span\u003e Setting menus for default page, pulse output, alarm thresholds, delays, communication settings, and counters \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p\"\u003e\u003cb\u003eEnvironment \u0026amp; Protection:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p\"\u003e– Operating: – °C; IP front panel\u003c\/p\u003e\n\u003cp class=\"p\"\u003e– Galvanic isolation on RS‑ \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003cb\u003eCertifications:\u003c\/b\u003e\u003c\/span\u003e EN ; RoHS; CE; GS declaration available \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003cb\u003ePhysical Specs:\u003c\/b\u003e\u003c\/span\u003e  ×  ×  mm; weight ~. kg \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":55818512367990,"sku":"EB-286669233921","price":426.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_df1af422-fddf-4282-b523-9e9f2701445a.png?v=1750720578","url":"https:\/\/volt-werk.com\/products\/abb-dmtme-i-485-96-2csg163030r4022-96-96-mm-multifunction-panel-meter","provider":"VOLTWERK Handel","version":"1.0","type":"link"}