{"product_id":"abb-a41-513-100-2cma170508r1000-single-phase-80-a-direct-connected","title":"ABB – A41 513-100 (2CMA170508R1000) – Single-Phase 80 A Direct-Connected","description":"\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch\u003e\u003cb\u003eMain Features\u003c\/b\u003e\u003c\/h\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003cb\u003eManufacturer \u0026amp; Model\u003c\/b\u003e\u003c\/span\u003e: ABB A ‑, internal code CMAR \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/span\u003e: Direct-connected active energy meter for single-phase systems, up to  A, class B accuracy; MID-certified for billing-grade applications \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p\"\u003e\u003cb\u003eCurrent \u0026amp; Voltage Specs\u003c\/b\u003e\u003cspan class=\"s\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003eNominal current up to  A (direct connection) \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003eRated voltage: up to  VAC (phase-to-neutral) \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p\"\u003e\u003cb\u003eAccuracy \u0026amp; Standards\u003c\/b\u003e\u003cspan class=\"s\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cp class=\"p\"\u003eClass B (≈%) accuracy; compliant per MID, IEC standards \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p\"\u003e\u003cb\u003eCommunication \u0026amp; I\/O\u003c\/b\u003e\u003cspan class=\"s\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003eIntegrated M‑Bus for remote energy readout \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003e configurable I\/O terminals—pulse outputs (S), tariff switching, import\/export monitoring, and integrated clock function \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p\"\u003e\u003cb\u003eDisplay \u0026amp; Form Factor\u003c\/b\u003e\u003cspan class=\"s\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003eBacklit, pixel-oriented display for energy and power metrics \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003eDIN-rail,  TE width; dimensions ~ mm wide, IP housing \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p\"\u003e\u003cb\u003eApplication Environment\u003c\/b\u003e\u003cspan class=\"s\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p\"\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003eOperational temperature range: – °C to + °C\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p\"\u003eDesigned for industrial panel installation and utility-compliant energy monitoring \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":55818559586678,"sku":"EB-286669234575","price":208.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_ff57186f-ec18-4e55-a6ea-1e5f7a2c36af.png?v=1750721317","url":"https:\/\/volt-werk.com\/products\/abb-a41-513-100-2cma170508r1000-single-phase-80-a-direct-connected","provider":"VOLTWERK Handel","version":"1.0","type":"link"}