{"title":"VEGA","description":"\u003cp\u003eIndustrial parts from VEGA: Process Instrumentation \u0026amp; Measurement, PLCs \u0026amp; Industrial Controllers and Control \u0026amp; Signaling Devices. Shipped from Germany.\u003c\/p\u003e","products":[{"product_id":"vega-vegatrenn-152-trenn152-amxskxx-2-channel-hart-isolating-barrier","title":"VEGA – VEGATRENN 152 (TRENN152.AMXSKXX) – 2-Channel HART Isolating Barrier","description":"\u003cp class=\"p1\"\u003eThe VEGA VEGATRENN 152 (model TRENN152.AMXSKXX) is a compact 2-channel passive isolating barrier for intrinsically safe 4–20 mA\/HART loops. It’s loop-powered (15–35 V DC) and supports full bidirectional HART communication, making it ideal to bridge Ex-approved sensors into non-Ex systems safely—certified for Ex zones and SIL 2 environments. \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch3\u003e\u003cb\u003eKey Features \u0026amp; Technical Specifications:\u003c\/b\u003e\u003c\/h3\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003c\/b\u003e\u003c\/span\u003e VEGATRENN 152 (TRENN152.AMXSKXX) – 2-channel HART isolator\/breaker\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eLoop-Powered:\u003c\/b\u003e\u003c\/span\u003e 15–35 V DC, no external power needed \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eChannels:\u003c\/b\u003e\u003c\/span\u003e 2 × 4–20 mA with bidirectional HART support; up to 5 HART devices per channel \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eLoop Voltage:\u003c\/b\u003e\u003c\/span\u003e ≥16 V at 4–20 mA (≤3 V drop at 4 mA; ≤5 V at 20 mA) \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eHART Access:\u003c\/b\u003e\u003c\/span\u003e Transparent HART via front jacks or terminals \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eCertifications:\u003c\/b\u003e\u003c\/span\u003e ATEX \/ IECEx Ex approval, SIL 2, CSA, EAC, NEPSI, UKCA \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eIngress\/IP Rating:\u003c\/b\u003e\u003c\/span\u003e IP20; DIN-rail mountable (35×7.5 mm); coded removable terminals \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eOperating Range:\u003c\/b\u003e\u003c\/span\u003e −20…+60 °C; \u0026lt;20 mV output ripple, \u0026lt;40 µA output current ripple \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eDimensions\/Weight:\u003c\/b\u003e\u003c\/span\u003e 113 × 52 × 20 mm; ~150 g\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":55818372350326,"sku":"EB-286669234609","price":189.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_b3d198ca-754f-4b38-8a3d-b159a96fccb8.png?v=1750716596"},{"product_id":"vega-vegator-132-tor132-axxxkxx-dual-channel-level-controller","title":"VEGA – VEGATOR 132 (TOR132.AXXXKXX) – Dual-Channel Level Controller","description":"\u003cp class=\"p1\"\u003eThe VEGA VEGATOR 132 (TOR132.AXXXKXX) is a dual-channel signal conditioner designed for conductive EL-series probes, offering reliable level detection and pump control in industrial applications. Compact and DIN-rail mountable with coded terminals, it features two independent control relays and failsafe diagnostics—ideal for alarm or control logic in process systems. \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch3\u003e\u003cb\u003eKey Features \u0026amp; Technical Specifications:\u003c\/b\u003e\u003c\/h3\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003c\/b\u003e\u003c\/span\u003e TOR132.AXXXKXX – VEGATOR 132 dual-channel controller \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eInputs:\u003c\/b\u003e\u003c\/span\u003e 2 × conductive probe inputs (EL series) – suitable for level monitoring or min\/max control \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eOutputs:\u003c\/b\u003e\u003c\/span\u003e 2 × SPDT relay outputs; max 3 A DC or 3 A AC @ 230 VAC \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003ePower Supply:\u003c\/b\u003e\u003c\/span\u003e 24–230 VAC (±15%) or 24–65 VDC; ≤2 W power consumption \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eFault Detection:\u003c\/b\u003e\u003c\/span\u003e Integrated line-break and short-circuit monitoring with LED indicators \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eMounting:\u003c\/b\u003e\u003c\/span\u003e DIN-rail (35×7.5 mm); detachable, coded screw terminals; IP20 housing \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eEnvironment:\u003c\/b\u003e\u003c\/span\u003e –20…+60 °C operating; IP20 rated; compact footprint (~113 × 55 × 20 mm)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eCertifications:\u003c\/b\u003e\u003c\/span\u003e ATEX, IEC approvals for industrial use; UL\/CE marked \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":55818376970614,"sku":"EB-286669234616","price":189.05,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_8e6fe8be-52c7-44f6-88ae-612233032c03.png?v=1750716693"},{"product_id":"vega-vegamet-142-trenn142-0-0-1-3-isolator-compact-controller-2-channel","title":"VEGA – VEGAMET 142 (TRENN142-0-0-1-3) Isolator  Compact Controller \u0026 2-Channel","description":"\u003cp class=\"p1\"\u003eThis bundle includes the VEGA VEGAMET 142 compact signal controller and the VEGATRENN 142 (TRENN142‑0‑0‑1‑3) 2-channel HART isolating barrier—offering an integrated solution for measurement, control, and intrinsically-safe loop separation. Ideal for industrial applications involving sensors with 4–20 mA signals and HART communication, this setup ensures safe Ex-area interfacing with intelligent control.\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch3\u003e\u003cb\u003e VEGAMET 142 – Compact Signal Controller\u003c\/b\u003e\u003c\/h3\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eInputs:\u003c\/b\u003e\u003c\/span\u003e 2 × 4–20 mA (configurable active\/passive) \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eOutputs:\u003c\/b\u003e\u003c\/span\u003e 2 × 0\/4–20 mA outputs; 3 × SPDT relays (one fail-safe) \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eDisplay \u0026amp; Interface:\u003c\/b\u003e\u003c\/span\u003e Graphic backlit LCD; rotary push-button; Bluetooth configuration \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eApprovals \u0026amp; Mounting:\u003c\/b\u003e\u003c\/span\u003e ATEX\/IECEx, c-UL-us, UKEX; DIN-rail, IP20, –20…+60 °C \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/span\u003e Pump\/level control, weir flow measurement, overfill protection, differential\/totalizer functions \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch3\u003e\u003cb\u003e TRENN142 – 2‑Channel HART Isolating Barrier\u003c\/b\u003e\u003c\/h3\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eFunction:\u003c\/b\u003e\u003c\/span\u003e Loop-powered galvanic separator for 2 × 4–20 mA\/HART lines \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003ePower:\u003c\/b\u003e\u003c\/span\u003e 15–35 V DC loop-powered; no external supply needed \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSafety \u0026amp; Certifications:\u003c\/b\u003e\u003c\/span\u003e Ex‑approved for intrinsically safe areas; SIL 2; supports full HART bidirectional communication \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eMounting \u0026amp; Build:\u003c\/b\u003e\u003c\/span\u003e DIN‑rail with coded screw terminals; IP20; –20…+60 °C \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e \u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":55818447225206,"sku":"EB-286669229328","price":521.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_fae4940d-008f-4a21-ad9b-f1335fa967f6.png?v=1750718092"},{"product_id":"vega-vegatrenn-141-4-20-ma-hart-signal-barrier-isolator","title":"VEGA – VEGATRENN 141 – 4–20 mA HART Signal Barrier \/ Isolator","description":"\u003cp class=\"p1\"\u003eThe VEGA VEGATRENN 141 (TRENN141.AxxxKxx) is a single-channel, loop-powered signal barrier that provides galvanic separation, intrinsic safety, and bidirectional HART communication for 4–20 mA sensors. Designed for hazardous locations, it supplies sensors intrinsically safely and enables full HART access via front sockets or terminals. \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch3\u003e\u003cb\u003e🔧 \u003c\/b\u003e\u003c\/h3\u003e\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel \/ P\/N:\u003c\/b\u003e\u003c\/span\u003e VEGATRENN 141, TRENN141.AxxxKxx \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eType:\u003c\/b\u003e\u003c\/span\u003e Single-channel Ex barrier for 4–20 mA\/HART loops \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003ePower Supply:\u003c\/b\u003e\u003c\/span\u003e 24–230 VAC or 24–65 VDC; loop-powered sensor supply. \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eOutput Signal:\u003c\/b\u003e\u003c\/span\u003e 4–20 mA retransmitted; ≤26 mA short-circuit current; \u0026lt;50 mV ripple RMS \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eHART Support:\u003c\/b\u003e\u003c\/span\u003e Full bidirectional transparency; sockets at the front under hinged cover \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eIsolation:\u003c\/b\u003e\u003c\/span\u003e Galvanic separation between sensor and output loops; Ex ia-rated for hazardous zones \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eApprovals:\u003c\/b\u003e\u003c\/span\u003e ATEX, IECEx, SIL 2, CE, c‑UL‑us, NEPSI, EAC, UKCA \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eOperating Range:\u003c\/b\u003e\u003c\/span\u003e –20…+60 °C; IP20; rail-mounted (35×7.5 mm); detachable, coded terminals \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003c\/span\u003e Approx. 113 × 56 × 20 mm; ~150–200 g\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":55818457547126,"sku":"EB-286669235115","price":94.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_074f1ca0-ec00-4970-a1b9-bdcdd4707e0b.png?v=1750718324"},{"product_id":"vega-vegatrenn-141-single-channel-hart-signal-barrier-loop-powered-ex-rate","title":"VEGA – VEGATRENN 141 – Single-Channel HART Signal Barrier, Loop-Powered, Ex-Rated","description":"\u003cp class=\"p1\"\u003eThe VEGA VEGATRENN 141 is a single-channel isolating barrier for 4–20 mA HART sensor loops in hazardous areas. Designed to provide galvanic separation between the field and control systems, it supports full bidirectional HART communication and operates as a loop-powered device—no external supply required. Ideal for Ex Zone 0\/1 applications.\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp class=\"p3\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Model: VEGATRENN 141 (TRENN141.AXXXKXX)\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Channels: 1 × 4–20 mA HART (passive loop-powered)\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Power Supply: 15–35 V DC (loop-powered)\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Voltage Drop: ≤5 V at 20 mA\u003c\/p\u003e\u003cp class=\"p1\"\u003e• HART Support: Bidirectional communication via terminals or front sockets\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Intrinsic Safety: Ex-approved (ATEX, IECEx, SIL 2)\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Mounting: DIN-rail (35 mm), removable coded terminals\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Operating Temp: –20 °C to +60 °C\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Enclosure: IP20, slim design (~113 × 20 × 56 mm)\u003c\/p\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":55818479927670,"sku":"EB-286669235187","price":94.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_40d89dfd-8d0e-4861-92a1-c2d2b450865a.png?v=1750719266"},{"product_id":"vega-vegatrenn-142-2-channel-hart-signal-barrier-loop-powered-ex-rated","title":"VEGA – VEGATRENN 142 – 2-Channel HART Signal Barrier, Loop-Powered, Ex-Rated","description":"\u003cp class=\"p1\"\u003eThe VEGA VEGATRENN 142 (TRENN142.AXXXKXX) is a dual-channel isolating barrier for integrating 4–20 mA HART loops from hazardous zones into safe-area control systems. It provides galvanic isolation, supports bidirectional HART communication, and requires no external power due to its loop-powered design. Suitable for Ex Zone 0\/1 applications, with SIL 2 certification for safety-critical processes.\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp class=\"p3\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Model: TRENN142.AXXXKXX\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Channels: 2 × 4–20 mA HART (passive loop-powered)\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Power Supply: 15–35 V DC (loop-powered)\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Voltage Drop: ≤5 V at 20 mA\u003c\/p\u003e\u003cp class=\"p1\"\u003e• HART Support: Full bidirectional communication\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Safety Approvals: ATEX, IECEx, SIL 2\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Mounting: DIN-rail (35 mm), coded removable terminals\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Operating Temp: –20 °C to +60 °C\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Housing: IP20; slim DIN-compatible profile (~113 × 52 × 20 mm)\u003c\/p\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":55818487464310,"sku":"EB-286669233843","price":284.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_5aa63e17-6852-4208-b9f8-f268b9c32ec4.png?v=1750719595"},{"product_id":"vega-vegamet-141-trenn152-amxskxx-4-20-ma-controller-2-channel-hart","title":"VEGA – VEGAMET 141 (TRENN152.AMXSKXX) – 4–20 mA Controller \u0026 2-Channel HART","description":"\u003cp class=\"p1\"\u003eThe VEGA VEGAMET 141 is a compact DIN-rail mounted controller and display unit for single-channel 4–20 mA sensors. Designed for applications like pump control, level measurement on flumes\/weirs, and overfill protection, it integrates a graphic backlit display, three control relays (with one configurable as fail-safe), and wireless Bluetooth parameterization.\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp class=\"p3\"\u003e\u003cb\u003eKey Features \u0026amp; Technical Specifications:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp class=\"p4\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003c\/b\u003e\u003c\/span\u003e VEGAMET 141 — 4–20 mA input\/output, DIN-rail \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eInput\/Output:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e1 × 4–20 mA sensor input (active\/passive selectable)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e1 × 0\/4–20 mA current output \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e3 × SPDT relays (1 configurable as fail-safe)\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eDisplay \u0026amp; Control:\u003c\/b\u003e\u003c\/span\u003e Graphic LCD (black\/white) with turn\/push button and backlight; icon-based menus \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eUser Interface:\u003c\/b\u003e\u003c\/span\u003e Bluetooth 5.0 for smartphone\/PC configuration \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eApprovals:\u003c\/b\u003e\u003c\/span\u003e ATEX, IEC, c-UL-us, UKEX; IP20 rated \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003ePower \u0026amp; Environment:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003eInput AC 100–230 VAC or DC 24–65 VDC\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003ePower ≤10 VA \/ 3 W; Operating: –20…+60 °C \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eMounting \u0026amp; Build:\u003c\/b\u003e\u003c\/span\u003e DIN-rail (35×7.5 mm), removable coded screw terminals; compact for control cabinets \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":55818494116214,"sku":"EB-286669233868","price":331.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_da22112d-481c-41bd-9af2-56198c17e0a3.png?v=1750719983"},{"product_id":"vega-vegatrenn-142-trenn142-0-0-1-3-2-channel-hart-signal-barrier","title":"VEGA – VEGATRENN 142 (TRENN142-0-0-1-3) – 2-Channel HART Signal Barrier","description":"\u003cp class=\"p1\"\u003eThe \u003cspan class=\"s1\"\u003e\u003cb\u003eVEGA VEGATRENN 142 (TRENN142‑0‑0‑1‑3)\u003c\/b\u003e\u003c\/span\u003e is a dual-channel intrinsic-safety isolating barrier engineered for 4–20 mA + HART sensor loops from hazardous areas. It supplies sensors within Ex-rated zones, provides galvanic isolation to safe-area instrumentation, and offers full bidirectional HART support—ideal for safe integration without requiring external power. \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s3\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s3\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch3\u003e\u003cb\u003eKey Features \u0026amp; Technical Details\u003c\/b\u003e\u003c\/h3\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s3\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003c\/b\u003e\u003c\/span\u003e TRENN142‑0‑0‑1‑3 (VEGATRENN 142) — double-channel active isolator\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSensor I\/O:\u003c\/b\u003e\u003c\/span\u003e 2 × 4–20 mA\/HART loops; supports up to 5 HART multidrop devices per channel \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003ePower Supply:\u003c\/b\u003e\u003c\/span\u003e Loop-powered from 24–31 V DC (–15 %\/+10 %) — no separate 24 V required \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eOutput Specs:\u003c\/b\u003e\u003c\/span\u003e Active 2 outputs, terminal voltage 16.5–21 V @ 4–20 mA, ≤26 mA short-circuit current; ripple \u0026lt;50 µV RMS \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eHART Transparency:\u003c\/b\u003e\u003c\/span\u003e Full bidirectional HART access via front jacks or terminals; passthrough of sensor commands \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSafety \u0026amp; Certifications:\u003c\/b\u003e\u003c\/span\u003e ATEX\/IECEx intrinsic safety, SIL 2 rated; IP20 housing; operating –20…+60 °C \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eMounting:\u003c\/b\u003e\u003c\/span\u003e DIN-rail (35×7.5 mm) with detachable coded screw terminals; compact form (~113 × 52 × 20 mm) \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eIndicators \u0026amp; Design:\u003c\/b\u003e\u003c\/span\u003e Front LEDs for power\/fault; hinged front cover for HART jacks  \u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":55818522362230,"sku":"EB-286669233939","price":236.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_2ca02908-5e19-46af-9870-9c753e4c0188.png?v=1750720636"},{"product_id":"vega-vegatrenn-142-trenn142-axxxkxx-2-channel-hart-barrier","title":"VEGA – VEGATRENN 142 (TRENN142.AXXXKXX) – 2-Channel HART Barrier","description":"\u003cp class=\"p1\"\u003eThe VEGA VEGATRENN 142 (TRENN142.AXXXKXX) is a double-channel signal isolator designed to integrate intrinsically-safe 4–20 mA\/HART sensor loops into safe-area control systems. It provides loop-powered galvanic isolation, ATEX\/IECEx approvals, SIL 2 safety, and full bidirectional HART transparency via front sockets or terminals. Ideal for hazardous-area installations requiring uncompromised signal integrity and access. \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch3\u003e\n\u003cb\u003e \u003c\/b\u003e\u003cb\u003eKey Features \u0026amp; Technical Specs:\u003c\/b\u003e\n\u003c\/h3\u003e\u003cp\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003c\/b\u003e\u003c\/span\u003e TRENN142.AXXXKXX – 2 × 4–20 mA\/HART isolator\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003ePower Requirements:\u003c\/b\u003e\u003c\/span\u003e Loop-powered from 24–230 VAC or 24–65 VDC; no external 24 V DC needed \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eSensor Loop Specs:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e2 active input channels (4–20 mA\/HART)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003eTerminal voltage 16.5–21 V DC at 4–20 mA; short-circuit current \u0026lt; 26 mA \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eOutput:\u003c\/b\u003e\u003c\/span\u003e 2 × isolated 4–20 mA retransmission; ripple \u0026lt; 50 µA RMS \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eHART Access:\u003c\/b\u003e\u003c\/span\u003e Full bidirectional transparency via front sockets or terminals \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eIsolation \u0026amp; Safety:\u003c\/b\u003e\u003c\/span\u003e Galvanic separation; Ex-approved for hazardous zones, SIL 2 certified; IP20 housing, operating –20…60 °C \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eInstallation:\u003c\/b\u003e\u003c\/span\u003e DIN-rail (35 mm), coded screw terminals, polycarbonate housing; LEDs for status indication\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":55818534650230,"sku":"EB-286669233970","price":284.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_fe129d5e-b871-4326-aab9-4788b82f7f71.png?v=1750720736"},{"product_id":"vega-vegatrenn-152-2-channel-isolating-barrier-ex-rated-4-20-ma-hart","title":"VEGA – VEGATRENN 152 – 2-Channel Isolating Barrier, Ex-Rated 4–20 mA HART","description":"\u003cp class=\"p1\"\u003eThe VEGATRENN 152 (TRENN152.A0XXKBX) is a two-channel galvanic isolator used to separate intrinsically safe (Ex-area) 4–20 mA HART sensor loops from non‑safe instrumentation circuits. Loop-powered and passive on the output side, it supports bidirectional HART communication without external power, making it ideal for process control in hazardous locations (ATEX Zone 0\/1). \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp class=\"p3\"\u003e\u003cb\u003eKey Features \u0026amp; Technical Specifications:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp class=\"p4\"\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003c\/b\u003e\u003c\/span\u003e VEGATRENN 152 (TRENN152.A0XXKBX) – double‑channel passive isolating barrier\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eInput\/Output:\u003c\/b\u003e\u003c\/span\u003e 2 x 4–20 mA HART lines, supports up to 5 HART multidrop devices per channel \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003ePower:\u003c\/b\u003e\u003c\/span\u003e Loop-powered (15–35 V DC) – no external power required \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eLoop Voltage:\u003c\/b\u003e\u003c\/span\u003e ≥16 V at 4–20 mA (≤5 V drop at 20 mA with 15 V supply) \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eHART:\u003c\/b\u003e\u003c\/span\u003e Fully transparent bidirectional HART signal access via front jacks or terminals \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eMounting \u0026amp; Connections:\u003c\/b\u003e\u003c\/span\u003e DIN-rail (35×7.5 mm) with coded, removable screw terminals; IP20 housing \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eOperating Condition:\u003c\/b\u003e\u003c\/span\u003e –20 °C to +60 °C; SIL 2 safety rating; approvals: ATEX, IEC, CSA, EAC, NEPSI, UKCA \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eRipple \u0026amp; Isolation:\u003c\/b\u003e\u003c\/span\u003e Output ripple \u0026lt; 40 µA RMS; input ripple \u0026lt; 20 mV RMS; galvanic separation between channels and output side \u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":55818547396982,"sku":"EB-286669234031","price":236.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_1963f887-8ec8-4b76-a5f4-11925a31c6ff.png?v=1750720907"},{"product_id":"vega-vegatrenn-152-trenn152-amxskxx-2-channel-hart-signal-barrier","title":"VEGA – VEGATRENN 152 (TRENN152.AMXSKXX) – 2-Channel HART Signal Barrier","description":"\u003cp class=\"p1\"\u003eThe VEGA VEGATRENN 152 (TRENN152.AMXSKXX) is a dual-channel intrinsically safe signal barrier designed for separating 4–20 mA HART sensor loops in hazardous environments. It enables galvanic isolation between field and control equipment while supporting full bidirectional HART communication. With its loop-powered design, no external supply is required, making it ideal for Ex Zone 0\/1 installations.\u003c\/p\u003e\u003cp class=\"p2\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp class=\"p3\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Model: TRENN152.AMXSKXX\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Channels: 2 × 4–20 mA HART (passive loop-powered)\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Power Supply: 15–35 V DC (loop-powered)\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Voltage Drop: ≤5 V at 20 mA\u003c\/p\u003e\u003cp class=\"p1\"\u003e• HART Support: Bidirectional communication via front sockets or terminals\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Intrinsic Safety: Ex-approved (ATEX, IECEx, SIL 2)\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Mounting: DIN-rail (35 mm), removable screw terminals\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Temperature Range: –20 °C to +60 °C\u003c\/p\u003e\u003cp class=\"p1\"\u003e• Enclosure: IP20, compact profile ~113 × 52 × 20 mm\u003c\/p\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":55818557751670,"sku":"EB-286669234552","price":141.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_129eea16-1592-4f08-ae94-a4b78978d303.png?v=1750721249"},{"product_id":"vega-vegamet-381-met381-ck-signal-conditioning-controller-display-instrument","title":"VEGA Vegamet 381 MET381.CK – Signal-Conditioning Controller \/ Display Instrument","description":"\u003cp class=\"p1\"\u003eVEGA Vegamet 381 MET381.CK – Signal‑Conditioning Controller \/ Display Instrument\u003c\/p\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":56671944474998,"sku":"EB-286944020984","price":379.05,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_0cd33760-65d7-4e27-a24a-900c0eeb5439.png?v=1763314558"},{"product_id":"vega-vegasel-441-b-444-limit-switch","title":"VEGA – VEGASEL 441 B (444) – LIMIT SWITCH","description":"VEGA – VEGASEL 441 B (444) – LIMIT SWITCH","brand":"VEGA","offers":[{"title":"Default Title","offer_id":57776213262710,"sku":"VW26-0662","price":84.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_36a30074-6724-4b24-920e-7d91e0752e7b.jpg?v=1777503703"},{"product_id":"vega-b62-36g-overvoltage-arrester-surge-protector-for-4-20-ma-hart","title":"VEGA – B62-36G – Overvoltage Arrester \/ Surge Protector (for 4...20 mA\/HART)","description":"\u003cp\u003eOvervoltage Arrester \/ Surge Protector (for 4...20 mA\/HART)\u003c\/p\u003e","brand":"VEGA","offers":[{"title":"Default Title","offer_id":58467215114614,"sku":"VW26-2344","price":84.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/4202\/8857\/files\/57_326e42a1-98c7-44ce-b69a-0c39e6b2785b.jpg?v=1787269355"}],"url":"https:\/\/volt-werk.com\/collections\/vega.oembed","provider":"VOLTWERK Handel","version":"1.0","type":"link"}